A&D GX-A/GF-A Series analytical balance with 0.1mg readability; 123g–10.1kg capacity.

Model GX-224A
Capacity 220g
Readability 0.0001g (0.1mg)
Pan Size Ø90 mm
Pan Shape Round (Ø90 mm)
In stock — available from UAE, KSA & Pakistan

Series Key Features

Ultra-high precision 0.1mg readability
Internal calibration mass (GX-A models)
GLP/GMP/ISO compliance
Touchless sensor switch
Stainless steel pan
Windows Communication Tools (WinCT)

GX-A/GF-A Series overview

The A&D GX-A/GF-A Series (Apollo) is a range of 35 analytical and precision balances offering 0.1 mg (0.0001 g) readability across capacities from 123 g to 10.1 kg. Built around A&D Japan's Super Hybrid Sensor (SHS) technology, the series delivers fast, stable weighing — typically under 1.5 seconds — making it suited to high-throughput laboratory, pharmaceutical, and food-quality work. GX-A models include an internal calibration mass for automatic span adjustment that compensates for ambient temperature change, a practical advantage in UAE laboratory environments; GF-A models use external calibration at a lower price point. Both lines share a stainless-steel pan, a touchless sensor switch to reduce contamination, GLP/GMP/ISO-compatible data output, and A&D's WinCT Windows communication software for direct PC data capture. The Apollo Series replaced the discontinued GX/GF generation and is A&D Gulf's flagship general-purpose weighing line for laboratories, R&D departments, and production QC teams across the UAE and GCC. A&D Gulf supplies the series from stock in Jebel Ali (JAFZA), Dubai, with internationally traceable calibration certificates, UAE & GCC delivery, and factory-trained technical support.

Technical Specifications

Full model-by-model data for procurement and quality teams. Supplied by A&D Gulf from Jebel Ali, Dubai.

Model-by-model technical specifications for GX-A/GF-A Series
Model Capacity Pan Size Readability Repeatability Linearity
GX-224A 220g Ø90 mm 0.0001g (0.1mg) 0.0001g ±0.0002g
View All Remaining Models & Complete Technical Sheet (34 more variants)
Model Capacity Pan Size Readability Repeatability Linearity
GF-123A 122g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GF-124A 122g Ø90 mm 0.0001g (0.1mg) 0.0001g ±0.0002g
GF-203A 220g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GF-224A 220g Ø90 mm 0.0001g (0.1mg) 0.0001g ±0.0002g
GF-303A 320g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GF-324A 320g Ø90 mm 0.0001g (0.1mg) 0.0002 g (300 g) / 0.0001 g (200 g) ±0.0003 g
GF-403A 420g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GF-603A 620g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GF-1003A 1100g 128mm x 128mm 0.001g (1mg) 0.001g ±0.003 g
GF-1202A 1220g 165 × 165 mm 0.01g 0.01g ±0.02g
GF-1603A 1620g 128mm x 128mm 0.001g (1mg) 0.002 g (1600 g) / 0.001 g (1000 g) ±0.003 g
GF-2002A 2200g 165 × 165 mm 0.01g 0.01g ±0.02g
GF-3002A 3200g 165 × 165 mm 0.01g 0.01g ±0.02g
GF-4002A 4200g 165 × 165 mm 0.01g 0.01g ±0.02g
GF-6001A 6200g 165 × 165 mm 0.1g 0.1g ±0.1 g
GF-6002A 6200g 165 × 165 mm 0.01g 0.01g ±0.03 g
GF-10001A 10200g 165 × 165 mm 0.1g 0.1g ±0.1 g
GF-10002A 10200g 165 × 165 mm 0.01g 0.02 g (10000 g) / 0.01 g (5000 g) ±0.03 g
GX-124A 122g Ø90 mm 0.0001g (0.1mg) 0.0001g ±0.0002g
GX-203A 220g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GX-303A 320g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GX-324A 320g Ø90 mm 0.0001g (0.1mg) 0.0002 g (300 g) / 0.0001 g (200 g) ±0.0003 g
GX-403A 420g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GX-603A 620g 128mm x 128mm 0.001g (1mg) 0.001g ±0.002g
GX-1003A 1100g 128mm x 128mm 0.001g (1mg) 0.001g ±0.003 g
GX-1202A No GX-1202A exists. The 1220 g / 0.01 g column is GF-1202A ONLY 128mm x 128mm 0.01g 0.01g ±0.02g
GX-1603A 1620g 128mm x 128mm 0.001g (1mg) 0.002 g (1600 g) / 0.001 g (1000 g) ±0.003 g
GX-2002A 2200g 165 × 165 mm 0.01g 0.01g ±0.02g
GX-3002A 3200g 165 × 165 mm 0.01g 0.01g ±0.02g
GX-4002A 4200g 165 × 165 mm 0.01g 0.01g ±0.02g
GX-6001A 6200g 165 × 165 mm 0.1g 0.1g ±0.1 g
GX-6002A 6200g 165 × 165 mm 0.01g 0.01g ±0.03 g
GX-10001A 10200g 165 × 165 mm 0.1g 0.1g ±0.1 g
GX-10002A 10200g 165 × 165 mm 0.01g 0.02 g (10000 g) / 0.01 g (5000 g) ±0.03 g

Compare series

Select up to two series from this category to compare side by side.

Currently viewing

GX-A/GF-A Series

Capacity range
122 g to 10200 g
Best readability
0.0001g (0.1mg)
Models available
35
Primary use
Laboratory & Research
Key features
  • Ultra-high precision 0.1mg readability
  • Internal calibration mass (GX-A models)
  • GLP/GMP/ISO compliance
  • Touchless sensor switch

Select a series
to compare

Select a series
to compare

GX-224A — Frequently Asked Questions

What is the A&D GX-224A analytical balance?
The GX-224A is an analytical model in the Apollo GX-A/GF-A series — 220 g capacity, 0.0001 g (0.1 mg) readability, with an internal calibration mass and a typical minimum weight of 120 mg. It is used for quantitative analysis, sample preparation, and precious metal weighing where the last decimal place matters. If you need true semi-micro resolution of 0.00001 g (0.01 mg), that is the A&D GH-252 or GH-202 rather than the GX-A range.
What is the difference between the GX-224A and GF-224A?
The GX-224A includes an internal calibration mass for automatic self-calibration; the GF-224A is the same balance calibrated with external weights. If your laboratory experiences temperature swings or you want calibration without operator intervention, choose the GX-A version.
Is the GX-224A suitable for gold and jewellery weighing in Dubai?
Yes. Its 0.1 mg readability and automatic internal calibration make it well suited to jewellery manufacturing QC and gold counter weighing, where temperature fluctuations would otherwise cause drift. A&D Gulf supplies it with an internationally traceable calibration certificate for your quality records. Where a balance prices a transaction by weight it is separately subject to UAE legal metrology: type approval and verification come from MOIAT, and in Dubai the verification is carried out by Dubai Municipality's Dubai Central Laboratory. Tell us how you trade and we will advise on the verification route.
Does the GX-224A produce GLP/GMP-compliant records?
Yes. The Apollo series provides GLP/GMP/ISO-compliant output with WinCT software support for direct data transfer to a PC — standard requirements for regulated pharmaceutical and food laboratories.

Regional Support · Jebel Ali Free Zone (JAFZA)

Full Lifecycle Support from Dubai's Precision Hub

A&D Gulf operates from Jebel Ali Free Zone — the GCC's premier logistics and trade gateway. We provide factory-authorised calibration, spare parts, and application engineering for every A&D instrument we supply, backed by direct manufacturer support from A&D Japan.

  • Pre-sale specification & demo
  • JAFZA-bonded stock, fast UAE delivery
  • On-site installation & commissioning
  • Internationally traceable calibration certificates
  • Preventive maintenance contracts
  • Direct A&D Japan technical escalation
JAFZA
Licensed & Bonded Distributor
Jebel Ali Free Zone Operations
A&D
Authorized distributor
Japan-manufactured instruments
ISO
Traceable calibration
Certificates on request
GCC
Regional coverage
UAE · KSA · Qatar · Kuwait
Chat