A&D Motorized Pipettes & ISO 8655 Pipette Testing
A&D Gulf FZE · Jebel Ali Free Zone, Dubai · Since 1986
A&D brings two things to the bench: motorized single-channel pipettes from 0.3 µL to 10 mL, and — the part most suppliers can't offer — the balance-based equipment to verify any pipette against ISO 8655. Dispense, then prove it.
0.3 µL–10 mL
MPA/PA volume range
5
motorized models
ISO 8655
gravimetric testing
Any brand
pipettes verified
A pipette is only as good as its last verification — accuracy drifts quietly (a worn seal, a dropped tip) until a result is questioned. A&D covers both halves: the MPA / PA series motorized single-channel pipettes (0.3 µL–10 mL, ~1,800 cycles per Li-ion charge, 96-well multi-dispense), and — its real strength — the gravimetric equipment to prove the volume.
Because A&D is a balance-maker first, it builds the testers: the AD-4212-PT / FX-300i-PT accuracy testers and the BH-014 kit that turns a BH balance into an ISO 8655-2:2022 calibration station — verifying any brand of pipette. Tell us your volumes and we'll specify it in 24 hours. Pair with calibration service.
MPA / PA Motorized Pipettes
Single-channel electronic pipettes — match the model to your working volume.
MPA-10 (PA-10)
Motorized single-channel, 0.3–10 µL. Sub-microlitre work with 0.1 µL volume increments.
Enquire →MPA-20 (PA-20)
Motorized single-channel, 0.3–20 µL. 0.1 µL increments for low-volume assays.
Enquire →MPA-200 (PA-200)
Motorized single-channel, 3–200 µL — the everyday routine-lab workhorse, 1 µL increments.
Enquire →MPA-1200 (PA-1200)
Motorized single-channel, 15–1200 µL for reagent and buffer handling.
Enquire →MPA-10000 (PA-10000)
Large-volume single-channel, 0.1–10 mL — replaces two manual pipettes; multi-dispense fills a full 96-well plate from one aspiration.
Enquire →ISO 8655 Pipette-Testing Ecosystem
Verify any brand of pipette gravimetrically — A&D's metrology advantage.
AD-4212B-PT / AD-4212A-PT / FX-300i-PT
Pipette accuracy testers — precision weigh modules built for gravimetric pipette verification down to 2 µL, with ISO 8655 pass/fail judgment.
Enquire →
BH-014 Kit
Turns a BH-series balance into a gravimetric pipette-calibration station: evaporation trap, sample cups, thermometer and WinCT-Pipette software with automatic mass-to-volume conversion and ISO 8655-2:2022 pass/fail.
Enquire →AD-1690
Pipette leak tester — checks seal integrity, the failure that quietly skews every dispense.
Enquire →AD-1695
Pipette Professional — management software for tracking test history, schedules and compliance records across a pipette fleet.
Enquire →Pipettes & ISO 8655 Testing FAQ — UAE & GCC
Which pipette do I need for my volume range?
Can you calibrate or verify the pipettes we already own?
What is ISO 8655 and do these meet it?
How long does the MPA battery last?
Do you supply pipettes and testing equipment in the UAE and GCC?
Dispense It. Then Prove It.
A&D motorized pipettes and ISO 8655 gravimetric testing equipment — supplied from Jebel Ali with a quote within 24 hours, across the UAE and GCC.
A&D Gulf FZE · Jebel Ali Free Zone (JAFZA), Dubai · +971 4 881 9900